B-stock Anybus Ab7633 Gateway X Gateway EtherNet/IP Modbus TCP See text/photo
B-stock Anybus Ab7633 Gateway X Gateway EtherNet/IP Modbus TCP See text/photo
second-circle
Low stock: 1 left
Couldn't load pickup availability
Right of withdrawal , Lieber Deem Billiger Shop (Shoes Shop) shipping and returns , Matterhorn Moda textiles shipping and returns , Jens Gallay jewelry shipping and returns,
contact
contact
Scope of delivery
- Quick Start Guide
- USB configuration cable
- Configuration software available for download
- Anybus OPC Server Software (OPC Classic for Windows) available for download
- Power adapter not included
Description
Anybus X-gateway – EtherNet/IP Adapter – Modbus TCP Server. The Anybus X-gateway connects an EtherNet/IP network to a Modbus TCP network, enabling seamless information flow between the two PLC systems. FAST I/O DATA TRANSFER BETWEEN TWO NETWORKS. The X-gateway is primarily designed for transferring cyclic I/O data between the two networks, thus relieving the PLC of additional tasks. The gateway acts as a slave in the EtherNet/IP network and a server in the Modbus TCP network. Data transmission is transparent, and up to 512 bytes of I/O data can be transferred in each direction. EASY COMMISSIONING – NO PROGRAMMING REQUIRED. The connection between the two networks is configured using the "Anybus Configuration Manager" software. No programming knowledge is required. The factory default setting for I/O data transfer is 20 bytes. Features and Benefits: Fast exchange of cyclic I/O data between the EtherNet/IP and Modbus TCP networks (10-15 ms); Compatible with PLCs from leading manufacturers; Supports up to 512 bytes of input and output data in each direction; Ability to create custom web pages, e.g., for diagnostic purposes; Anybus OPC Server with OPC DA support enables fast, dynamic transfer of fieldbus data to higher-level, Windows-based systems such as SCADA/HMI; Control and status information can be added to the I/O data for diagnostic purposes; Robust stand-alone housing for use in harsh industrial environments; Qualified, personal support
Details
- Type: Modbus-TCP Slave/Modbus-TCP Slave
- Operating voltage: 24
- Maximum operating temperature: +65
- Minimum operating temperature: -25
- Operating temperature: -25 to +65 °C
- Dimensions: (W x H) 44 mm x 127 mm
- Maximum current draw: 400
- Height: 127
- Width: 44
- Version: Anybus Modbus-TCP Slave/Modbus-TCP Slave Gateway
- Current consumption: 200 mA
- Plastic-free packaging: Plastic-free packaging
- Product type: Gateway
Share